Setting the masking volumes can be approached in
two ways:
IDEAL: If a sound level meter is available, adjust
the unit’s masking volumes to achieve the following
readings on a sound level meter.
Sound Level Meter Readings
Open Areas Zones:
45 – 48 dBA, measured three (3) feet above floor level
Private Office Zones:
38 – 42 dBA, averaged spatially within the office
OTHERWISE: If a sound level meter is not available,
the proper levels are likely to be achieved in most
environments by setting the unit’s masking volumes
as follows:
Qt PRO™ Masking Volume Settings
Open Area Zones:
Volume level 13 – 16, for 8' ceilings
Volume level 15 – 18, for 10' ceilings
Volume level 17 – 20, for 12' ceilings
Private Office Zones:
Volume level 05 – 09 (or higher), for all ceiling
heights
Masking volumes must be set sufficiently high to
improve speech privacy and reduce distractions,
but not so high that the masking sound becomes
objectionable. Settings within the above ranges should
accommodate both objectives. As a general rule, set
masking volumes toward the high end of the range,
but base final settings on site conditions and customer
preferences. It is highly recommended that the system
be turned on when the space is unoccupied to avoid
drawing attention to the masking sound. If a space is
occupied, the volume may be ramped over time. To
do this, refer to “Volume Ramping” on page 10.
Paging Volume Adjustment
If paging is to be supported, adjust paging sensitiv-
ity
and paging volume. Qt PRO™ provides two paging
inputs, each of which is connected to all zones. You
must adjust paging sensitivity for each paging input
signal and paging volume for each paging output to
each zone.
Paging sensitivity is used to gain (±) the incoming
paging signal to match the range of Qt PRO™’s
circuitry. It is adjusted for each paging input. Once
adjusted, volumes are set for each zone by adjusting
the zone’s paging (A and/or B) volumes.